FRP Duct that carries
what steel cannot

Wet acidic exhaust destroys galvanised and coated steel ductwork from the inside. GRP ducting has no coating to fail. We build rectangular and circular ducts, fume extraction runs and stack liners, with nozzles and access openings moulded in.

Rectangular and Circular Fume Duct Stack Liner Vinyl ester + C-veil Made in Vietnam
GRP duct run into an FRP exhaust stack on a plant roof
Product Range

Three forms, one material

Ducting is rarely a catalogue item. Cross-section, routing and support points are set by the building, so almost every job is designed and built to the specific installation.

DUCT CONSTRUCTIONRound and rectangular duct, flanged or laminatedTwo sections, two joint types. We build all four.0102030401FLANGED JOINT · ROUNDFlat-face GRP ring flange, moulded on and drilled.Bolts apart for equipment tie-ins and inspection.02LAMINATED JOINT · ROUNDButt and strap overlay in the same resin. The wallbecomes continuous, so there is no gasket to fail.03FLANGED JOINT · RECTANGULARRectangular GRP flange frame, drilled to the samepattern. Same logic on a flat section.04LAMINATED JOINT · RECTANGULAROverlay wrapped around the full perimeter. Used onlong fixed runs that never need to come apart.The section comes from the space you have. The joint comes from whether the run has to come apart later.

Round and rectangular sections, joined by bolted flange or laminated butt and strap.

Round GRP duct spool with external stiffener rings.
Round GRP duct spool with external stiffener rings.

Illustrative images, not project photographs.

Rectangular GRP exhaust duct spool with perimeter stiffener ribs
TYPE 01

Rectangular Duct

The usual choice inside buildings, where a rectangular section fits the available ceiling space better than a round one. Flat panels carry less load than a cylinder, so stiffener design does the work.

  • Hand lay-up, panel and stiffener construction
  • Flanged sections for site assembly
  • Access doors and instrument ports moulded in
  • Cleanroom and process exhaust
Filament wound circular GRP duct spool
TYPE 02

Circular Duct

Structurally the most efficient section, and the preferred choice for longer runs and higher negative pressure. Filament wound in the same way as pipe.

  • Filament wound, uniform wall thickness
  • Long runs with fewer joints
  • Elbows, tees and reducers to match
  • Scrubber inlet and outlet ducting
GRP stack liner segment with moulded stiffening ring
TYPE 03

Stack Liner

A GRP liner inside an existing steel or concrete stack. The structure stays, the corroding surface is replaced. Often the cheaper answer to a failing stack.

  • Retrofit into existing stack structure
  • Wet acidic and condensing service
  • Sectional build for site assembly
  • Post-FGD and scrubber discharge
Design

Specification

ItemDetail
SectionRectangular, circular, and transition pieces between the two
Size rangeCircular DN100 to DN3000. Rectangular sized to the installation, no fixed limit
ResinVinyl ester for wet acidic exhaust. Isophthalic for general ventilation. Fire-retardant grade to ASTM E84 Class I where required
LinerC-veil for acid service. Synthetic veil for general service
ReinforcementExternal ribs and stiffeners, spacing set by the negative pressure case
JointingBolted flange joint, or laminated butt and strap overlay. Both are standard for round and rectangular sections
Integral fittingsAccess doors, damper frames, drain points, instrument ports, support lugs
StandardsASTM D2996 (wound sections), ASTM E84 (fire-retardant grade), client specification

Sizes above are our normal working range. If your scope falls outside it, send the specification and we will confirm whether we can build it.

Negative pressure decides the design

An exhaust duct spends its life under suction. Internal pressure is easy to design for, because it pushes the wall into tension where the laminate is strongest. Suction does the opposite, and a duct that fails does so by buckling inward, not by bursting.

  • Fan static pressure  the design case, including the blocked-filter condition
  • Stiffener spacing  the main variable, set from the buckling calculation rather than from wall thickness alone
  • Rectangular panels  flat spans need more support than a curved section of the same area
  • Support points  hanger positions come from the same calculation, not chosen on site

This is why we ask for flow rate, fan pressure and the routing before quoting. Duct that is priced on area alone is priced without knowing what holds it up.

Square GRP duct spool with stiffener ribs around the perimeter

Send the flow rate and the fan curve

Gas composition, operating temperature, flow rate, fan static pressure and the routing are enough for us to size the section and the stiffeners. A layout sketch is fine, drawings are not required.