Filament-wound and hand-laid FRP/GRP tanks built for the chemicals power plants actually store, including sulfuric acid, caustic soda, sodium hypochlorite, ammonia, ferric chloride, demineralized water, and limestone slurry. ASTM D3299 / BS 4994 / KS M 3403 compliant.
Pick the geometry that fits your plot plan. Leeho engineers adapt the laminate schedule and nozzle layout to your service.
TYPE 01
TYPE 02
TYPE 03
TYPE 04
Each FRP storage tank ships with a standard nozzle set. We add custom nozzles for your specific instrumentation, agitation, and process needs.
500 mm or 600 mm diameter access for inspection, cleaning. Davit-mounted blind cover.
Open or weather-hooded vent sized for fill/empty rate. Optional flame arrestor for hazardous service.
Top or side, with internal anti-impingement deflector to protect liner.
Magnetic float, sight glass, or radar nozzle. Visual scale or 4–20 mA transmitter.
Top-entry mixer mounting flange with stiffener ring for shaft loads.
Side or bottom drain, sloped pad for full evacuation. Flanged or threaded.
Bottom-side, sized for design pump-out flow. Includes internal flange reinforcement.
4 or 8 hot-dip galvanized lugs for foundation hold-down. Sized to wind & seismic.
The same precision-controlled winding process that builds aerospace pressure vessels, applied to your power-plant tank.
Hand-laid surface veil + chemical barrier resin on a polished steel mandrel. 100% resin-rich layer.
Glass roving impregnated in resin bath, wound at programmed helix angles for hoop & axial strength.
Ambient cure or thermally accelerated. Mandrel extracted, end domes hand-laid in place.
Nozzles laminated in place, hydro test, Barcol hardness, visual & UT inspection, top coat applied.
Right resin, right barrier, right service life.
| Service | Concentration | Recommended Resin | Max Temp | Tank Type |
|---|---|---|---|---|
| Sulfuric Acid | ≤ 75% / 93–98% | Vinyl Ester (DERAKANE 470) VE | 40 °C | Vertical · Double-wall |
| Hydrochloric Acid | ≤ 37% | Vinyl Ester (DERAKANE 411) VE | 50 °C | Vertical |
| Sodium Hydroxide | ≤ 50% | Iso-Polyester / Vinyl Ester ISO | 60 °C | Vertical · Horizontal |
| Sodium Hypochlorite | ≤ 12% | Vinyl Ester (DERAKANE 470) VE | 30 °C | Vertical (vented) |
| Ferric Chloride | ≤ 40% | Vinyl Ester (DERAKANE 470) VE | 50 °C | Vertical |
| Ammonium Hydroxide | ≤ 28% | Iso-Polyester ISO | 40 °C | Vertical (closed) |
| Limestone Slurry | ≤ 30 wt% | Vinyl Ester w/ wear liner VE+ | 65 °C | Vertical (agitated) |
| Demin / Condensate Water | – | Iso-Polyester ISO | 90 °C | Horizontal |
| Diesel / Lubricant | – | Vinyl Ester / Bisphenol-A VE | 50 °C | Underground |
| Process Water (Treated) | – | Iso-Polyester ISO | 60 °C | Vertical / Horizontal |
Send us your service chemical, capacity, and plot constraints, and we issue dimensioned drawings within 5 working days.
Request Tank Quotation →